(Q.L.F.T.): A pass/fail fit test to assess the adequacy of respirator fit that relies on the individual's response to the test agent.
Related Terms |
BUBBLE POINT
The differential gas pressure at which the first steady stream of gas bubbles is emitted from a wetted filter element under specified test conditions.
|
A.S.T.M.
American Society for Testing Materials - a society for developing standards for materials and test methods.
|
FABRICATION INTEGRITY POINT
The differential gas pressure at which the first stream of gas bubbles are emitted from a wetted filter element under standard test conditions.
|
FILTER LIFE TEST
A type of filter capacity test in which a clogging contaminant is added to the influent of a filter, under specified test conditions, to produce a given rise in pressure drop across the filter or until a specified reduction of flow is reached. Filter life may be expressed as test time required to reach terminal conditions at a specified contaminant addition rate.
|
BETA RATING
the method of comparing filter performance based on efficiency. This is done using the Multi-Pass Test which counts the number of particles of a given size before and after fluid passes through a filter.
|
BETA-RATIO (ß-RATIO)
The ratio of the number of particles greater than a given size in the influent fluid to the number of particles greater than the same size in the effluent fluid, under specified test conditions (see 'Multi-Pass Test').
|
FTIR, Fourier Transform Infrared Spectroscopy
A test where infrared light absorption is used for assessing levels of soot, sulfates, oxidation, nitro-oxidation, glycol, fuel, and water contaminants.
|
PAPER CHROMATOGRAPHY
A method which involves placing a drop of fluid on a permeable piece of paper and noting the development and nature of the halos, or rings, surrounding the drop through time. The roots of this test can be traced to the 1940s, when railroads used the 'blotter spot' tests.
|
POUR POINT
Lowest temperature at which an oil or distillate fuel is observed to flow, when cooled under conditions prescribed by test method ASTM D 97. The pour point is 3°C (5°F) above the temperature at which the oil in a test vessel shows no movement when the container is held horizontally for five seconds.
|
PATCH TEST
A method by which a specified volume of fluid is filtered through a membrane filter of known pore structure. All particulate matter in excess of an 'average size', determined by the membrane characteristics, is retained on its surface. Thus, the membrane is discolored by an amount proportional to the particulate level of the fluid sample. Visually comparing the test filter with standard patches of known contamination levels determines acceptability for a given fluid.
|