feedback
Enter marine-related query and AI bot will look for best match in our DB.
 

This Refrigeration system usually used one of three refrigerants on merchant ship like Freon, ammonia and carbon dioxide, and the method of expansion system can be divided in two categories either direct or indirect.
The system where the refrigerant, at low pressure and temperature, enters the suction side of the compressor through a scale trap, compression take place and refrigerant leaves the compressor, at high pressure and temperature, passes through oil separation which removes oil from it. Then flows through suitable piping of condenser where sea water is circulated and remove heat from the gas refrigerant, change into liquid form collected by liquid receiver and passes out through the king valve or liquid valve leading to expansion valve, then absorbs heat and become gas or vapor, led back again to the compressor and repeat the cycle.



Related Terms

DIRECT EXPANSION SYSTEM

A system where the evaporation is in direct contact with the material or space refrigerated or the refrigerant itself extracts the heat from the space to be cooled.

INDIRECT EXPANSION SYSTEM

The refrigeration system where the refrigerant is evaporated into the coils of the evaporator, which are in a brine tank, thus the brine secondary refrigerant is circulated to the coil of the cold storage chamber to do the cooling instead the coil with the refrigerant inside.

Related questions

MarineProHelp 2018 - 2020

First time here? Check out the FAQ!

If you've arrived to new location and wonder how to dress comfortably according to weather, check Comfiesto

×